Transas Engine Room Simulator ERS 4000 ver.7.3
-
Skraćeni naziv instrumenta
Transas ERS 4000 ver. 7.3
Opis na stranicama zavoda/laboratorija
http://www.pfri.uniri.hr/web/hr/radni_prostor_i_oprema.php
Year of manufacture
2007
-
Ustanova en
Sveučilište u Rijeci, Pomorski fakultet
Studentska 2, RijekaGrad
Rijeka
Ulica i broj
Studentska ulica 2
Krilo/Kat/Soba
410 A
-
Način korištenja instrumenta
, , , ,
Termini tečajeva za korisnike
http://www.pfri.uniri.hr/web/hr/cip.php
-
Ime i prezime
Dean Bernečić
E-mail
bernecic@pfri.hr
Telefon
+385 (0)51 338 411
Faks
+385 (0)51 336 755
-
Ime i prezime
Darko Glujić
E-mail
glujic@pfri.hr
Telefon
+385 (0)51 338 411
Faks
+385 (0)51 336 755
-
Model
Transas Engine Room Simulator - ERS 4000 ver.7.3
Mrežna (URL) adresa instrumenta na stranicama proizvođača
http://www.transas.com/products/simulation/engine-room-and-cargo-handling-simulators/ERS5000
Mrežna (URL) adresa proizvođača
http://www.transas.com
Purchase price
1000000
Datum nabave
1.1.2007
Detaljne tehničke karakteristike
The Simulator consists of 6 working (student) computers and one instructor (lecturer) station.
The maximum capacity for the simulator classroom is 12 students.
There are two moduls.
Module 1 simulates 65 000 dwt LCC tanker with a MAN B&W 6 S 60 diesel engine and all necessary auxiliary systems. The electrical plant includes main switchboard, two diesel generators, one turbo generator, one shaft generator, an emergency switchboard, a shore supply switchboard and power transformers. Auxiliary plant includes steam plant system, ballast system, bilge water system, steering gear system, water desalination plant, sewage treatment system, incinerator, inert gas system, fire alarm system, foam and CO2 systems, provision cooling and air conditioning system.
Module 2 simulates 137 585 m3 LNG tanker with a 29540 kW cross-compound, double reduction geared main propulsion steam turbine type Kawasaki UA – 400. The propulsion plant also includes two Mitsubishi main water tube boilers with dual fuel burners and internal economizers, two turbo generators and one diesel generator. The electrical plant voltage is 6600 V and frequency is 60 Hz. Auxiliary plant is the same as in the module 1.
Both modules include evaluation and assessment system intended for the quantitative assessment of the students’ performance during the fulfillment of an exercise.
The Instructor station software consists of three modules:
• On-line class – for teaching and monitoring the execution of exercises by the students;
• Exercise Editor – creating new exercises and editing existing ones;
• Debriefing – viewing and debriefing recorded exercises.
The engine room simulator can also be integrated with NTPro 4000 navigational simulator.Mrežna (URL) adresa s tehničkim karakteristikama
http://www.transas.com/products/simulation/engine-room-and-cargo-handling-simulators/ERS5000