Radon detector RM-2 (radon in soil)

Radon detector RM-2 (radon in soil)
  • Skraćeni naziv instrumenta

    Radon detector RM-2 (radon in soil)

    Inventarni broj

    1400000001147

    Opći opis

    Radon detector RM-2 consists of a set of fifteen ionization chambers IK-250, the reader ERM-3 and a soil-gas sampling set. Samples of soil-gas are collected through hollow steel rods by means of a plastic large-volume syringe and transferred to evacuated ionization chambers. In order to eliminate thoron, ionization chambers with soil-gas samples are measured with specific time delay of 15 minutes after sampling. Alpha radiation of radon in soil-gas sample give rise to ionization current in the ionization chamber, which is measured within 120 s. The pre-programmed, fully automatic reader ERM-3, with installed calibration constant, displays the concentration of radon in units of volume activity (kBq/m3).

    Uža područja primjene

    Applied nuclear physics, radioactivity, radon

    Namjena instrumenta

    Determination of the activity concentration of radon Rn-222 in soil

    Year of manufacture

    2014

  • Ustanova en

    Sveučilište Josipa Jurja Strossmayera u Osijeku, Odjel za fiziku
    Trg Ljudevita Gaja 6, Osijek

    Zavod

    Chair for the experimental physics

    Laboratorij

    Laboratory for low-level radioactivity

    Grad

    Osijek

    Ulica i broj

    Trg Ljudevita Gaja 6

    Krilo/Kat/Soba

    ground floor and first floor

  • Način korištenja instrumenta

    ,

    Popis ovlaštenih korisnika

    Vanja Radolić
    Marina Poje Sovilj
    Denis Stanić
    Igor Miklavčić
    Branko Vuković

    Broj istovrsnih instrumenata u ustanovi

    1

  • Opis tržišne prilike

    Measurement of the activity concentration of radon Rn- 222 in soil.

  • Ime i prezime

    Vanja Radolić

    Titula

    Associate professor

    E-mail

    vanja@fizika.unios.hr

    Telefon

    +385 31 232 700

    Faks

    +385 31 232 701

  • Ime i prezime

    Marina Poje Sovilj

    Titula

    Assistant professor

    E-mail

    marina.poje@fizika.unios.hr

    Telefon

    + 385 31 232 727

    Faks

    +385 31 232 701

  • Model

    Radon detector RM-2 (radon in soil)

    Mrežna (URL) adresa instrumenta na stranicama proizvođača

    http://www.radon-vos.cz/?lang=en&lmenu=en_measuring&page=en_measuring_rm2

    Proizvođač

    radon v.o.s.

    Mrežna (URL) adresa proizvođača

    http://www.radon-vos.cz/index.php

    Purchase price

    55.292

    Estimated current value of equipment

    31.101

    Mrežna (URL) adresa s tehničkim karakteristikama

    http://www.radon-vos.cz/?lang=en&lmenu=en_measuring&page=en_measuring_rm2

    Popratna i dodatna oprema

    An additional set of 15 ionisation chambers for soil air sampling.